1. 庄闲和游戏

      AMI System Solution
      AMI System Solution


      Functions
      Administration

      Meter Administration
      Concentrator Administration
      Monitoring of System Components Replacement History
      Monitoring of Command and Parameter History of System Components
      Defining of Roles and Users/User Groups
      Access Control to System Components and AMR Centre
      Administration of reporting functions of AMI Centre
      Regular Automatic Backup of All Data At the Desired Time

      Data Reading/Collection and Archiving

      Reading of Individual Concentrator/meter

      Reading of the Group of Concentrators/Meters

      Automated Reading According to the Sequence

      Reading On Request

      Periodical Reading on Request

      Special Reading on Request

      Data collected automatically according to the sequence set in advance include the following

         Daily Register Values

         Meter States

         Electricity Quality Log

         Event Log

         Load Profile

         Hourly Register Values

         State of Monthly Accounting Registers

         Time and Date


      Data collected from the meter on request including:

         Effective Voltage Values Per Phases At the Moment of Reading

         Effective Current Values Per Phases At the Moment of Reading

         Current Power–(Load Power At the Moment of Reading)

         Tariff Programmer

         Integration Period for 15-Minute Maximum Power

         Consumption Management Parameters

         Parameters for Voltage Thresholds Within Electricity Quality Log

         Parameters or Time Intervals of Profiles

         Parameters for Registers Within Profiles

         Parameters Related to the Presentation On Meter Display

         Archive States of Accounting Registers

         Current State of Bi-stabile Switch

         Meter Software Version

         Factory Number and Type of Meter


       Data read according to the sequence from the concentrator including:

         Statistics of Communication / Emergency and Regular Reports


       Data read from the concentrator upon the request including:

         Concentrator Data Archive

         Reading Programmes/Sequences

         Management/Parameterisation Programmes/Sequences

         Programmes/Sequences Execution Priorities

         Communication Routes

         Concentrator Response Time and Frequency Parameters

         Communication Parameters of the Concentrator

         Current Date and Time

         Other Concentrator Parameters

         Concentrator Software Version

         Records on Concentrator Parameter Changes and Adjustments

      Reporting functions

      Reports with Analysis of Statuses and Alarms

       Reports on Electricity Quality

       Reports Related to Parameterization and Management

       Communication Reports

       Control Reports

       Reports Generated by the Concentrator

      Data and Information Exchange with Other Information Systems and Subsystems of Electric Utility Robust protocol library for various types of DCUs and electronic energy meters, DLMS/COSEM, IEC61870-5-102 compliant